Electrical Specification Overview:
1) Board Style: High Country Tek unique size and mounting.
2) Connector Type: 12 way male Deutsch DT series
3) Comms. I/O connector:
4 way Packard MALE ( Tower ) connector on 6 inch,
4 core umbilical cable.
4) Comms. Type: Serial data at 57.6K Baud through PC USB/Serial port.
5) Input Supply Voltage: 9 to 32VDC ( absolute maximums )
6) Input supply current: ~200mA quiescent + valve currents
7) Input supply protection: SAE J1455 & User supplied in-line fuse ( AGC5 )
8) Command Input types: SAE J1939 & 2 x external discrete thermistor/switch contact
9) Thermistor types: 2 wire Resistance variety only ( see table )
10) Thermistor Protection: Open and short circuit detection
11) Proportional valve current range: ~0 – 3000mA ( with current feedback circuit )
12) Directional valve current range: ~0 – 3000mA.
13) Output Protection: Open and short circuit detection
14) Alarm output current: ~0 – 3000mA.
15) ‘Reverse’ input signal value range: >+2.5VDC to +V module supply
16) ‘Reverse’ input signal impedance: >100K Ohm
17) Digital Input De-Bounce: 150mS ( triggered on rising edge )
18) Industry Compliance:
certification to latest standards
19) Environmental: Totally encapsulated unit for mechanical protection.
20) IP rating: IP68 ( Module only - derate for connectors as required )
21) NEMA rating: 6P ( Module only - derate for connectors as required )
22) Humidity: 95 – 100% Non-condensing
23) Storage Temp range: -60 to + 90 Deg C ( Max )
24) Operating temp range: -40 to + 85 Deg C ( max )
ALL controller and system response adjustments are made through graphical user interface software,
See ‘HFS-J Software’ section in this manual for full details.