Electronic Controller Solutions for the Global Fluid Power Industry
Hydraulic Fan System Controller with SAE J1939 Interface
HFS-J User Guide
Part No:- 021-00158 Rev C HFS-J Hydraulic Fan System Controller User Guide Page | 11
Error LED code descriptions:
Status LED
Reverse / Error LED Discription Alarm Output Fan Output Reverse Output NOTE
OFF OFF Power Supply < 9.3 VDC OFF OFF OFF 1
OFF OFF Power Supply > 30 VDC OFF OFF OFF 1
ON OFF Normal Operation OFF As Demanded As Demanded 2
ON OFF J1939 RPM Timeout OFF Min Current As Demanded 3
ON OFF Reverse Sequence Active OFF Reverse SPD % ON 2
ON Flashing J1939 Engine Coolant Timeout ON Min Current As Demanded 3
ON Flashing J1939 Transmission Temp Timeout ON Min Current As Demanded 3
ON Flashing J1939 Intake Man. Temp. Timeout ON Min Current As Demanded 3
Code = 1 Flashing J1939 Engine Coolant Over Temp ON Min Current As Demanded 3, 7
Code = 2 Flashing J1939 Intake Man. Over Temp ON Min Current As Demanded 3, 7
Code = 3 Flashing J1939 Transmission Over Temp ON Min Current As Demanded 3, 7
Code = 1 Flashing PWM Output Open ON Min Current OFF 4
Code = 2 Flashing PWM Output Short ON Min Current OFF 4
Code = 3 Flashing Alarm Output Short OFF Min Current OFF 3
Code = 5 Flashing Reverse Output Short ON Min Current OFF 3
Code = 1 Flashing
Unit Temp >80°C OFF OFF OFF 5
Code = 3 Flashing Thermistor 1 Short ON Min Current OFF 6
Code = 4 Flashing Thermistor 1 Open ON Min Current OFF 6
Code = 5 Flashing Thermistor 1 Over Temp ON Min Current OFF 6, 8
Code = 6 Flashing Thermistor 2 Short ON Min Current OFF 6
Code = 7 Flashing Thermistor 2 Open ON Min Current OFF 6
Code = 8 Flashing Thermistor 2 Over Temp ON Min Current OFF 6, 8
NOTES:
1 Wait for Correct Power
2 Normal Operation
3 Fan Output min current until corrected (Max Fan SPD)
4 Attempt to drive min current to fan until corrected
5
Wait until unit temp < 70°C
6 Fan Output min current until corrected (Max Fan SPD) Reverse Sequence Cancled
7 Reverse Cycle Operates Normaly
8 Reverse Cycle Normal If Reverse Input Switch is used and Overtemp Condition is present before start of cycle