P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 53
from 100% to 0%)
Name.Frequency Set PWM frequency 0 to 1000 for 0 to 100hz
Name.Dutycycle Ser PWM dutycycle 0 to 1023 for 0 to 100%
Name.Freqerror Returns error 1 = Frequency error,
2 means duty cycle error
HSEvenName Set the Bang-bang Coil to On or Off Off, On
HSEven#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil
Short]
HSEven#Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil
Open]
HSOddName Set the Bang-bang Coil to On or Off Off, On
HSOdd#Name.OpenDisable
Set the Disable Coil Open Detection 0 [Enabled], 1 [Disabled]
HSOdd#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil
Short]
HSOdd#Name.Open Get/Set the Coil Flag for Open Status Off [Coil Ok], On [Coil
Open]
Name.Cur Current actual * CurGain = amps 0 – 3.5 amps
Name.RampCur Current ramped Currend*CurGain= amps 0 – 3.5 amps
Name.CurErr Current Error = RampCur – Cur 16 Signed Integer
Name.CurSumErr Current Error accumulated over time 0 – 65535
Name.CurP Current Proportional Term Constant “P” 0 – 255
Name.CurI Current Proportional Term Constant “I” 0 – 255
Name.MinCurA Minimum Current Coil A *.001 = amps 0 – 3.5 amps
Name.MaxCurA Maximum Current Coil A *.001 = amps 0 – 3.5 amps
Name.Config Configuration Word – Output, Process,
Coil
Output Group Selected as PWM Disabled
Name Description Range
HSEvenName
Set the Bang-bang Coil to On or Off Off, On
HSEven#Name.OpenDisabl
e
Set the Disable Coil Open Detection 0 [Enabled], 1 [Disabled]
HSEven#Name.Short
Get the Coil Flag for Short Status Off [Coil Ok], On [Coil
Short]
HSEven#Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil
Open]
HSOddName Set the Bang-bang Coil to On or Off Off, On
HSOdd#Name.OpenDisabl
e
Set the Disable Coil Open Detection 0 [Enabled], 1 [Disabled]
HSOdd#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil
Short]
HSOdd#Name.Open Get/Set the Coil Flag for Open Status Off [Coil Ok], On [Coil
Open]
Enable Process PI Variables
The Name field is the Low-Side name. The default variable name is replaced with the specified name.
Name Description Range
Name.Setpoint
The desired % set point position for the
output
0 to 100%
Name.Feedback The % feedback position for the output 0 to 100%
Name.ProErr Error = Set point – Feedback 16 bit signed integer
Name.ProSumErr Error accumulated over time 0 – 65535
Name.ProP Process Proportional Term Constant “P” 0 – 255
Seitenansicht 52