High-country-tek MVP-C Series Bedienungsanleitung Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
021-MVP-Cxx-(D1) Rev A MVP-C-(D1) User Manual 21
Copyright © High Country Tek, Inc. 2013
MVP-Cxx-(D1) Valve Controller
Single Solenoid 2-speed Control
The MVP can be configured for 2-speed control.
When selecting mode 5, the Enable signal allows
minimum output.
The Command signal allows maximum output.
Single Solenoid 2-speed Control
The MVP can be configured for 2-speed control.
When selecting mode 6, the Enable signal allows
maximum output.
The Command signal allows minimum output.
FUSE
+V Power Input
9 - 28VDC
+V = Enabled
Brown PWR +
MVPC/D1
Electronic Valve
Controller
White Enable
GRN/YEL
Prop. PWM
(Sourcing)
Red Ref. Out
BLK Analog I/P
Blue GND
Connector GND
Screen
Fast
FUSE
+V Power Input
9 - 28VDC
+V = Enabled
Brown PWR +
MVPC/D1
Electronic Valve
Controller
White Enable
GRN/YEL
Prop. PWM
(Sourcing)
Red Ref. Out
BLK Analog I/P
Blue GND
Connector GND
Screen
Slow Down