023-00354-Rev1.6 evc/epc User Manual 5
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Controller Specification
48.5mm
125mm
58mm
4 3
9 10 11 12
2 1
6 5
7 8
114mm
C
L
2x Ø5
Controller Mounting Information
Mount controller in an easily accessible
location.
Mount controller to a flat, cool surface.
If mounting to a hydraulic product, allow at
least a 2mm air gap underneath the unit.
Use BOTH mounting holes with correct
hardware.
DO NOT mount controller with connector
facing UP if possible.
9 to 32VDC (Absolute maximum)
Valve current + 50mA Quiescent (Max)
2x switched inputs (ON/Off)
2x analog inputs:
One with (0-5V, 0-10V, 4-20mA)
One with (0-5V, 0-10V, Pulse or Freq. - 3 to
30KHz)
Voltage & Freq. inputs = 100k
2x 3A proportional PWM (Sourcing)
(Short circuit protection and open circuit alert)
1x 5VDC ±10% (Regulated voltage @ 250mA)
Software adjustable - 33 to 500Hz
-40 to +85ºC (Operational)