Hydraulic Fan System Controller HFS-3-12v
10
Plug driver unit onto valve coil to be driven.
Remove ‘HFS-3-12v securing screw
Remove ‘HFS-3-12v opaque lid to reveal internal adjustments.
Ensure command PWM signal is set to zero.
Ensure that all wire connections are correct and secure.
Turn I Min potentiometer 1 turn Anti-Clockwise ( Minimum ).
Turn I Max potentiometer 20 turns Clockwise ( Maximum ).
Apply 12VDC ( +10 to +14VDC absolute Maximum ) to the driver plug.
NON-INVERTED operation means that the output current follows the input command signal.
i.e. 10% PWM = Min O/P
90% PWM = Max O/P
This option is intended for use with a proportional flow control or variable pump electro-hydraulic stroker.
In this configuration, if the power supply fails, the fan unit will default to the OFF speed.
For this option to be activated, the user must remove ( by cutting ) link ‘A’, the location of which
is shown at the bottom of this page.
CAUTION:-
Link ‘A’, once removed, CANNOT be replaced.
Slowly increase command to approx 90% of maximum PWM.
Use the I Min adjustment to give minimum motor speed required.
Slowly Increase command signal to 10% of maximum setting.
Adjust I Max until desired motor maximum speed is achieved.
Check that ‘Output ON’ led is functioning proportionally by varying the command signal.
Ensure link ‘A’, is cut and REMOVED
Adjustment Guide:
NON-INVERTED valve control operation.
Link ‘A